Recalibration of the Soft X-Ray Telescope Onboard Yohkoh

Authors

Loren W. Acton

Publication

Solar Physics

Abstract

We present a new derivation of the X-ray spectral sensitivity of the Soft X-ray Telescope (SXT) experiment onboard Yohkoh. The recalibration is based upon the hypothesis that, during the first 15 months of the mission, an absorbing material gradually built up on the entrance filters of the telescope. We have also re-evaluated the times and sizes of ruptures of the SXT entrance filters. The impact of this recalibration on derived filter-ratio temperature, emission measure, and calculated spectral irradiance is substantial, especially for SXT data prior to November 1992.

Links

 

How is this information collected?

This collection of Montana State authored publications is collected by the Library to highlight the achievements of Montana State researchers and more fully understand the research output of the University. They use a number of resources to pull together as complete a list as possible and understand that there may be publications that are missed. If you note the omission of a current publication or want to know more about the collection and display of this information email Leila Sterman.